Ouput current derated 10.0 percent for 50 hz operation; dc output adjustment range plus or minus 5.0 percent ; output ripple 0.02 percent peak to peak, 0.01 percent rms ; foldback current limit with automatic recovery; stability, plus or minus 0.3 percent for 24 hours after warmup; temperature rating is derated linearly from full rated at 50 degrees c to 40.0 percent at 70 degrees c; vibration resistant per mil-std-810b, method 514, procedure 1, curve ab (to 50 hz); shock resistant per mil-std-810b, method 516, procedure v; ic regulated design; 2 hour burn-in; moving air or conduction cooling recommended if in confined area
NSN 5996-00-109-8172
NSN 5990-01-102-9617
NSN 5855-01-391-7472
NSN 5975-01-147-7879
NSN 6240-01-343-8111
NSN 5975-01-191-5226
NSN 4140-01-321-5784
NSN 6240-01-091-0264
NSN 5835-00-725-2087
NSN 5990-00-091-0669
NSN 6110-01-213-3246
NSN 4140-00-647-1142